Supplier PRP Blood Low Speed Mini Lab Centrifuge Manufacturer

Supplier PRP Blood Low Speed Mini Lab Centrifuge Manufacturer

Item NO.: KML1

To get price & sample,  

please click button Inquiry and leave your email, 

we will contact you within 12hrs!

Kangmin®

Kangmin® 10years Focus on Medical/Lab Supplies

Trusted Global Supplier&Manufacturer

FDA/CE/ISO Standard 

High Quality & Factory Directly Price 

Stock Fast Shipping Worldwide

Support Small Amount Order 

Support OEM Custom 

Support Free Sample 
24hrs Customer Service

Detail

  • MOQ: 1pcs
  • Price: $120-140

Supplier PRP Blood Low Speed Mini Lab Centrifuge Manufacturer

Color:White

Product information: 

A laboratory centrifuge is an instrument that uses the centrifugal force generated by a rotating rotor to separate substances of different densities and different particle sizes in a suspension or emulsion, or to perform analysis while separating. It has a wide range of applications and is suitable for laboratory use in chemical, food, pharmaceutical, environmental protection, mining, teaching and other laboratories. Commonly used laboratory centrifuges belong to the structure of a three-foot centrifuge with manual upper unloading.

Specifications:

Specifications Parameter
Speed Range 300-5000rpm, increment:10rpm
Max. RCF 2350xg, increment: 10g
Speed accuracy ±20rpm
Rotor capacity 6x15mL/10mL/7mL/1.5-5ml 
Run Time 30sec-99min, HD(continuous running)
Display LCD
Programs Memory 2
Acceleration/Deceleration  1↑ 2↓
Safety Devices Door interlock, Overspeed detector, Automatic internal diagnosis
Motor Brushless DC motor
Power Single-phase, 12V/24V,100V-240V,50Hz/60Hz, 70W
Dimension(WxDxH) 300X240X180mm
Weight 5.2kg

Advantage:

1.Low noise ≤20.2db
2.Portable
3.Mini

Application:

  • Medical Field 
  • Third-party testing institutions 
  • Laboratory 
  • Scientific research

Packing: in bulk or customized packing.

Market:

  • Qualification complete, contact sales for detailed certification. We can ship the face shield to many countries smoothly, like Germany, Franch, Canada, Australia, South Africa, Indonisia, Peru, Brazil and so on.

Production Capacity:100K-200K/Day

Guidelines for the use of centrifuges:

1. When the centrifuge is in the pre-cooling state, the centrifuge cover must be closed. After the centrifugation, the rotor should be taken out and placed on the test bench. The remaining water in the cavity is wiped off, and the centrifuge cover is open.

2. When the rotor is pre-cooled, the rotor cover can be placed on the platform of the centrifuge, or placed on the experimental table. It must be tightened and floated on the rotor, because once it is started by mistake, the rotor cover will be Will fly out and cause an accident!

3. After the rotor cover is tightened, there must be no gap between the rotor and the rotor cover with your fingers. If there is a gap, unscrew and re-tighten the centrifuge until it is confirmed that there is no gap.

4. During the centrifugation process, the operator shall not leave the centrifuge room. Once an abnormal situation occurs, the operator cannot turn off the power (POWER) and press STOP. Before pre-cooling, fill in the centrifuge usage records.

5. Do not use fake or inferior centrifuge tubes, and do not use aged, deformed, or cracked centrifuge tubes.

6. You can leave after the last routine safety check using the centrifuge during holidays and evenings.

7. If there is a machine failure during the use of the instrument, and the parts are damaged, please contact us in time.

Note:

At present, electric centrifuges are commonly used in laboratories. The electric centrifuges rotate at a fast speed. Pay attention to safety. In particular, prevent the centrifuge from moving while working due to imbalance or aging of the test tube pad during the operation of the centrifuge. The glass shards spun out after the centrifuge tube was broken due to vibration due to the falling off of the stage or the uncovered cover, causing an accident. Therefore, when using the centrifuge, you must pay attention to the following operations.

(1) Cotton or test tube pads should be placed at the bottom of the centrifuge casing.

(2) If the electric centrifuge is noisy or the body vibrates, the power supply should be cut off immediately, and the fault should be eliminated immediately.

(3) The centrifuge tube must be symmetrically placed in the casing to prevent the machine from vibrating. If there is only one sample tube, the other should be replaced with water of equal quality.

(4) When starting the centrifuge, cover the top cover of the centrifuge before starting slowly.

(5) After the separation, turn off the centrifuge first. After the centrifuge stops rotating, you can open the centrifuge cover and take out the sample. Do not use external force to force it to stop.

(6) The centrifugation time is generally 1 to 2 minutes. During this period, the experimenter is not allowed to leave to do other things.