China Manufacturer Blood Medical Fingertip Pulse Oximeter Monitor

China Manufacturer Blood Medical Fingertip Pulse Oximeter Monitor

Pulse Oximeter is used to check the blood oxygen content in the human body,measuring heart rate, blood oxygen and detect a person's pulse.

  • Type: medical fingertip pulse oximeter
  • Material: Plastic
  • Size: Measurement: 57mm(L)*31mm(W)*32mm(H),Weight:about 50g
  • Packing: Individual Packaging One set per one box
  • Usage: Pulse Oximeter is used to check the blood oxygen content in the human body,measuring heart rate, blood oxygen and detect a person's pulse.
  • Sample: Support
Quote Now
  • MOQ:
  • Price:

China manufacturer blood medical fingertip pulse oximeter monitor.

It is used for detection of blood oxygen saturation value and pulse rate value. Suitable for non-invasive monitoring of blood oxygen saturation and pulse rate in hospitals and homes.

Measurement: 57mm(L)*31mm(W)*32mm(H)

Weight:about 50g.

Function: 

  1.  Check the blood oxygen content in the human body
  2.  Measuring heart rate, blood oxygen
  3.  Detect a person's pulse

Product performance:

  • Display mode: 0.96" display
  • Blood oxygen saturation measurement range: 0%~100%
    Error: When the measurement range of blood oxygen saturation is 70% to 100%, the allowable absolute error is ±2%; less than 70% is undefined.
  • Pulse rate measurement range: 20bpm ~ 250bpm (resolution is 1bpm) accuracy: ±2bpm or ±2%, whichever is greater
  • Perfusion index measurement range: 0%~20%
    Error: When the measurement range of perfusion index is 1%~20%, the allowable absolute error is ±1%;
    When the measurement range of perfusion index is 0%~0.9%, the allowable absolute error is ±0.2%
  • Resolution: Blood oxygen saturation is 1%, pulse rate is 1bpm, perfusion index is 0.1%
    Error under weak perfusion: When the pulse filling degree is 0.4%, the oximeter can correctly display the blood oxygen saturation and pulse rate value, the blood oxygen saturation error is ±4%; the pulse rate error is ±2bpm or ±2% Take the larger value
  • Under normal conditions and ambient light conditions, the difference between the measured value of blood oxygen saturation is not more than 1% 
  • Power consumption: not more than 30mA
  • Working voltage: DC 3.0v
  • Battery: 2 AAA 1.5V alkaline batteries
  • Battery working hours: minimum continuous working 20 hours, theoretical value 36 hours
  • Safety type: BF type application part

Application:

  • Medical Field 
  • Inpatient Ward 
  • Laboratory 

Test Procedure:

  •  Put the finger into the automatic measurement
  •  Take out your fingers,automatically shut down to save power
  •  Built-in silicone,comfortable detectio

Packing: One Set Per box

Market:

  • Qualification complete, contact sales for detailed certification. We can ship the face shield to many countries smoothly, like Germany, Franch, Canada, Australia, South Africa, Indonisia, Peru, Brazil and so on.

Production Capacity:100K-200K/Day

How to use it?

  • 1. Insert two AAA batteries according to the positive and negative signs of the battery compartment and close the battery cover.

  • 2. Pinch the clip as shown in the figure below. When inserting the finger, the nail must be upward.

  • 3. Insert your finger into the rubber channel (it is best to extend your finger fully), and then release the clamp.

  • 4. Just press the switch button on the front panel.

  • 5. It is best not to shake your fingers during use, and it is best not to keep the human body in motion.

  • 6. Read the relevant data directly from the display screen. When you turn on the oximeter, every time you press the power switch, the oximeter will switch to another display mode.

  • Note: Before using this product again for testing, please wipe the rubber of the nail cover with medical alcohol, and wipe the tested fingers with medical alcohol before and after use. (The rubber material uses medical rubber, which is non-toxic, harmless, and will not cause side effects such as allergies to human skin)