Supplier Magnetic Bead Method Sample PCR Plate Test Nucleic Acid Extraction Kit

Supplier Magnetic Bead Method Sample PCR Plate Test Nucleic Acid Extraction Kit

Nucleic Acid Extraction Kit is suitable for rapid nucleic acid extraction of pathogens (such as HBV/HCV/HPV) in serum, PBS specimens, exfoliated cells and above specimens for subsequent molecular detection applications.

  • Type: Nucleic Acid Extraction Kit
  • Material: Plastic
  • Size: Deep well plate、PCR plate and others.
  • Packing: Individual Packaging One set per one box
  • Usage: Nucleic Acid Extraction Kit is suitable for rapid nucleic acid extraction of pathogens (such as HBV/HCV/HPV) in serum, PBS specimens, exfoliated cells and above specimens for subsequent molecular detection applications.
  • Sample: Support
Quote Now

Supplier Magnetic Bead Method Sample PCR Plate Test Nucleic Acid Extraction Kit

It is suitable for rapid nucleic acid extraction of pathogens (such as HBV/HCV/HPV) in serum, PBS specimens, exfoliated cells and above specimens for subsequent molecular detection applications.

Method: Magnetic Bead Method

Include:PCR plate、deep well plate、extraction tube and any other.

Function: 

  1.  Detect whether there is viral nucleic acid in the sample.
  2.  Effectively simplify time, get results in as fast as 2 hours.
  3.  Increased the daily detection efficiency.

Usually "false negatives" are caused by:

  • At the initial stage of virus invading the human body, the amount of virus in the human body has not reached a detectable level. In different periods of virus incubation period, mild symptoms, and severe symptoms, the viral load of different parts of the human body (such as nasopharynx, oropharynx, trachea, bronchi and alveoli) will be different. Therefore, different sampling timing and sampling locations may result in insufficient virus in the collected specimens.
  • Any test reagent has its lower detection limit (ie sensitivity). If the virus in the patient's sample does not reach the lower limit of the reagent used, a false negative will occur.
  • Poor performance of laboratory equipment and personnel, poor quality management, etc. will also produce "false negatives"
  • Irregular sampling, improper collection site, and atypical collection of specimens have resulted in too few or no virus-infected cells in the specimen. That may cause "false negatives".

Application:

  • Medical Field 
  • Inpatient Ward 
  • Laboratory 

Test Procedure:

  •  Collect specimens
  •  Extract and store the nucleic acid of the sample
  •  Amplify and replicate nucleic acid samples
  • Analyze whether the nucleic acid in the sample can be matched with the standard sample

Packing: One Set Per box

Market:

  • Qualification complete, contact sales for detailed certification. We can ship the face shield to many countries smoothly, like Germany, Franch, Canada, Australia, South Africa, Indonisia, Peru, Brazil and so on.

Production Capacity:100K-200K/Day

How to use it?

  • 1. First, the reagent preparation area is responsible for receiving patient samples.The reagent preparation area is the most "clean" area in the PCR laboratory. It should not contain any nucleic acid components, otherwise it will seriously affect the accuracy of the test results. The preparation of specimens should be carried out in a biological safety cabinet.

  • 2. Second, the sample preparation area is responsible for the extraction and storage of nucleic acids of the sample, and the production of amplification reaction tubes.

  • 3. Third, the amplification zone is to amplify and replicate nucleic acid samples. The configuration of the amplification reaction system and the extraction and addition of nucleic acids should be carried out in the amplification zone.

  • 4. Fourth, the analysis area after amplification is to analyze whether the nucleic acid in the sample can be matched with the standard sample. If it is detected by the instrument, it is judged as positive, and if it is not detected, it is negative.The working area should be set to a negative pressure state, and the air flow direction is from outside to inside to prevent the aerosol of the amplified product from flowing out.

SEND YOUR MESSAGE